Independent, 3rd Party Testing by LightLab International Allentown, LLC and Electropossible Ltd.
LIGHTLAB INTERNATIONAL
40 years of combined experience in photometry and testing with testing equipment selected carefully for accuracy and customization.
Website: LightLabAllentown.com
LightLab International Test Results
| Center Point Irradiance (350-1700nm) | Maximum Irradiance (350-1700nm) | Power | ||
|---|---|---|---|---|
| Irradiance (A108-GHz-Optik BTS2048-VL-TEC & A114-GHz-Optik BTS2048-NIR Spectral Irradiance Meters) mW/cm² Total Spectrum ULTRA |
6" | 85.70 | 111.20 | 800.6 W |
| 12" | 67.99 | 90.44 | ||
| 24" | 60.51 | 60.53 | ||
| 36" | 45.55 | 45.74 | ||
| 48" | 38.72 | 38.72 |
ELECTROPOSSIBLE LTD
Fully accredited electrical experts based in Milton Keynes, United Kingdom.
Website: electropossible.co.uk
Electropossible Test Results
| MINI | COMPACT | MAX | ULTRA | ELITE | ||
|---|---|---|---|---|---|---|
| Irradiance (Spectrometer HP350IR) mW/cm² Most accurate - This device can measure wavelengths from 550nms to 1100nms |
6" | 98.7 | 99.0 | 100.53 | 119.28 | 121.62 |
| 12" | 84.1 | 86.0 | 86.9 | 97.58 | 102.23 | |
| 24" | 59.0 | 63.2 | 68.65 | 71.77 | 74.91 | |
| 36" | 42.7 | 47.2 | 49.1 | 49.73 | 66.35 |
| MINI | COMPACT | MAX | ULTRA | ELITE | ||
|---|---|---|---|---|---|---|
| EMF (Cornet EMF Device) μT |
3" | ≈0.04 | ≈0.04 | ≈0.04 | ≈0.04 | ≈0.04 |
| 6" | ≈0.0 | ≈0.0 | ≈0.0 | ≈0.0 | ≈0.0 |
| MINI | COMPACT | MAX | ULTRA | ELITE | |
|---|---|---|---|---|---|
| Power Consumption (all LEDs at 100% intensity) Watts |
156 | 462 | 755 | 715 | 1552 |
| MINI | COMPACT | MAX | ULTRA | ELITE | |
|---|---|---|---|---|---|
| Decibel / Sound dB |
53 | 50.5 | 51 | 47 | 51 |
| MINI | COMPACT | MAX | ULTRA | ELITE | |
|---|---|---|---|---|---|
| Flicker | 0% | 0% | 0% | 0% | 0% |
More readings
The following readings are only provided for apples to apples comparison with other brands, that use the following equipment.
Images (Spectrometer Irradiance readings)
The following images show real proof of a variety of Irradiance readings obtained at certain distances from our devices.
Please note: Even at a constant distance, Irradiance varies when measured from different parts of the panel. This happens because of LED placement and wavelength composition. You will notice that at larger distances, the variation reduces because multiple LEDs contribute more homogeneously toward to the readings.
Irradiance readings at 0"
Irradiance readings at 3"
Irradiance readings at 6"
Irradiance readings at 12"
Irradiance readings at 24"
Irradiance readings at 36"
The following readings are only provided for apples to apples comparison with other brands, that use the following equipment.
| MINI | COMPACT | MAX | ULTRA | ELITE | ||
|---|---|---|---|---|---|---|
| Irradiance (Spectrometer HP350FR) mW/cm² Slightly inaccurate - This device can measure wavelengths from 380nms to 1000nms which misses the 1064nms |
6" | 98.32 | 110.57 | 125.96 | 133.76 | 139.18 |
| 12" | 86.29 | 95.43 | 107.84 | 117.15 | 128.36 |
| MINI | COMPACT | MAX | ULTRA | ELITE | ||
|---|---|---|---|---|---|---|
| Irradiance (Solar Power Meter) mW/cm² Not accurate - Solar power meters are not ideal for measuring LED Irradiance |
8" | 170 | 172 | 172 | 174 | 179 |
Images (Spectrometer Irradiance readings)
The following images show real proof of a variety of Irradiance readings obtained at certain distances from our devices.
Please note: Even at a constant distance, Irradiance varies when measured from different parts of the panel. This happens because of LED placement and wavelength composition. You will notice that at larger distances, the variation reduces because multiple LEDs contribute more homogeneously toward to the readings.
Irradiance readings at 0"
Irradiance readings at 3"
Irradiance readings at 6"
Irradiance readings at 12"
Irradiance readings at 24"
Irradiance readings at 36"
Images (EMF readings)